Uji Komparatif COP Domestik Refrigerator Multi Temperatur Menggunakan Evaporator Tunggal Dan Evaporator Ganda Dengan Katup EPR

Winarta, Adi and Santika, I Wayan Gede and Mulawarman, Anak Agung Ngurah Bagus (2013) Uji Komparatif COP Domestik Refrigerator Multi Temperatur Menggunakan Evaporator Tunggal Dan Evaporator Ganda Dengan Katup EPR. In: Seminar Nasional dan Pertemuan Peneliti Technopreneurship, 30-31 Oktober 2013, Bali, Indonesia.

[img] Text (Article)
senapatiadiwinarta-140321003756-phpapp01.pdf - Published Version

Download (834kB)

Abstract

Domestik refrigerator digunakan untuk menyimpan makanan beku (frozen food) yang mempunyai temperatur sekitar -18ºC dan juga makanan dingin (chilled food) berkisar 4ºC. Kedua level temperatur diatas biasanya dicapai dengan evaporator tersendiri. Evaporator pada mesin refrigerator domestik biasanya diletakkan pada bagian freezer atau bagian paling atas dan harus pula memberikan pendinginan pada ruang makanan dingin (chilled food). Dengan kata lain, evaporator tersebut harus mengatasi beban pendinginan di freezer yang memiliki temperatur rendah dan di chiller yang memiliki temperatur lebih tinggi. Sehingga bisa dikatakan harus bekerja pada tekanan rendah pada freezer dan tekanan lebih tinggi pada ruang makanan dingin (chiller). Pada penelitian ini diuji dua sistem domestik refrigerator untuk dua kompartemen yakni ruang penyimpan makanan beku (frozen food) dan ruang makanan dingin (chilled food). Masing-masing sistem diuji dengan beban pendingin 500 Watt untuk tiap ruangan pendingin. Kapasitas kompresor yang digunakan sebesar ⅓ HP (horse power) dan temperatur lingkungan dianggap konstan sebesar 29ºC. Dari hasil pengujian didapatkan bahwa COP rata-rata sistem refrigerasi evaporator ganda dengan EPR sebesar 5,33 sedangkan COP pada sistem evaporator tunggal tanpa EPR sebesar 5,2. Kata kunci: COP, domestik refrigerator, evaporator pressure regulator (EPR), evaporator multi temperatur. A Domestic refrigerator is used to hold a freezer temperatur at about -18C and food compartement temperatur near 4C, however these two levels of temperatur are achieved by only one evaporator. A single evaporator, located in freezer compartment, must cover both the food and freezer compartment. Therefore, it must operate at lowe pressure required by freezer section, which is must lower than that required by food compartement. In this case, due to high pressure difference between evaporator and condenser, the compressor work is relatively large, which result in degraded performance. Each of the system had been test with 500 watt heater load for each compartement. The compressor capacity which been used for this system about ⅓ HP. The test was conducted at outdoor temperature considerably constant at 29C. The research result shows that average COP for the double evaporator refrigerator with EPR valve about 5,33 and the other system has average COP about 5,2. Keyword: COP. Domestic refrigerator, evaporator pressure regulator (EPR), multi temperature evaporator

Item Type: Conference or Workshop Item (Paper)
Subjects: Ilmu Teknik > Ilmu Keteknikan Industri > Teknik Mesin (dan Ilmu Permesinan Lain)
Ilmu Teknik > Ilmu Keteknikan Industri > Teknik Refrigerasi
Ilmu Teknik > Ilmu Keteknikan Industri > Teknik Enerji
Divisions: Jurusan Teknik Mesin > Prodi D4 Teknologi Rekayasa Utilitas > Publikasi
Depositing User: I Wayan Gede Santika
Date Deposited: 15 May 2023 02:17
Last Modified: 15 May 2023 02:17
URI: http://repository.pnb.ac.id/id/eprint/5876

Actions (login required)

View Item View Item