Experimental Study of Thermoelectric Cooler Box using Heat Sink with U-shape Heat Pipe and Methanol Working Fluid

Winarta, Adi and Rasta, I Made and Midiani, Luh Putu Ike and Subagia, I Wayan Adi and Sapteka, Anak Agung Ngurah Gde (2021) Experimental Study of Thermoelectric Cooler Box using Heat Sink with U-shape Heat Pipe and Methanol Working Fluid. In: 2nd International Conference on Mechanical Engineering Research and Application (iCOMERA 2020), 7-9 October 2020, Malang, Jawa Timur, Indonesia.

[img] Text (Correspondences Document)
Korespodensi_ICOMERA.pdf - Other

Download (1MB)
[img] Text (Plagiarism Check Document)
Experimental study of thermoelectric cooler box using heat sink with u- shape heat pipe and methanol working fluid.pdf - Other

Download (2MB)
Official URL: https://iopscience.iop.org/article/10.1088/1757-89...

Abstract

Thermoelectric refrigeration system is considered environmentally friendly because it does not use refrigerants which have huge potential damaging the ozone layer. In this experimental work, u-shape heat pipe with heat sink was charged with methanol working fluid with different filling ratios to observe its effect on the thermoelectric performance. The cooler box has 240 mm x 180 mm x 130 mm of inner dimension. 37.3 watt DC power supply supplied constantly to the thermoelectric module to performed cooling action. The result shows that methanol with 45% and 55% filling ratios has the maximum COP about 0.03881 and 0.03885 respectively. This filling ratio also provides for a lower cabin temperature and temperature difference between the cold and hot thermoelectric sides.

Item Type: Conference or Workshop Item (Paper)
Subjects: Ilmu Teknik > Ilmu Keteknikan Industri > Teknik Refrigerasi
Divisions: Jurusan Teknik Mesin > Prodi D4 Teknologi Rekayasa Utilitas > Publikasi
Depositing User: Adi Winarta
Date Deposited: 27 May 2023 11:59
Last Modified: 27 May 2023 11:59
URI: http://repository.pnb.ac.id/id/eprint/6218

Actions (login required)

View Item View Item