Experimental Study Of Cooling Performance And Electrical Parameters In A Microcontroller-Driven Inverter AC System

Negara, I Gede Artha and Anakottapary, Daud Simon and Midiani, Luh Putu Ike and Temaja, I Wayan and Santosa, I Dewa Made Cipta (2023) Experimental Study Of Cooling Performance And Electrical Parameters In A Microcontroller-Driven Inverter AC System. INVOTEK: Jurnal Inovasi Vokasional dan Teknologi, 23 (2). pp. 81-90. ISSN 1411 – 3411

[img] Text (Similarity Check)
Similarity Check - Experimental Study of Cooling Performance and Electrical Parameters in a Microcontroller-Driven Inverter AC System.pdf - Supplemental Material
Available under License Creative Commons Attribution Non-commercial Share Alike.

Download (2MB)
[img] Text (Letter of Acceptance)
[INVOTEK] Letter of Acceptance.pdf - Supplemental Material
Available under License Creative Commons Attribution Non-commercial Share Alike.

Download (125kB)
[img] Text (Article Correspondence)
Korespondensi Artikel.pdf - Supplemental Material
Available under License Creative Commons Attribution Non-commercial Share Alike.

Download (360kB)
Official URL: http://invotek.ppj.unp.ac.id/index.php/invotek/art...

Abstract

Recent advancements in air conditioning (AC) technologies, such as inverters, enable the compressor to remain activated despite reaching the setpoint temperature. This study investigates the cooling performance and electrical parameters of a split inverter AC system controlled by a microcontroller in order to determine the operational performance characteristics of the air conditioning system. An ATmega 2560 microcontroller integrated with PZEM, DS18B20, and LCD I2C sensors monitors was 8,525 Btu/h capacity split inverter AC. During a 1-hour experimental run, the temperature differential between supply air (Tsupply) and return air (Treturn) stabilized at approximately 17 °C, with Tsupply reaching a minimum of 8.5 °C. Treturn remained relatively constant after 500 s with no fluctuations. Moreover, power draw maintained an average of 750 W (1 PK) with no variations, exhibiting an inverse relationship with Tsupply. The maximum energy consumption recorded during the experiment was 1,373 kWh. As expected based on fundamental thermodynamic principles, the energy usage showed a direct proportional relationship with the total runtime of the system. That is, the longer the AC system was engaged, the higher the total energy required to maintain the cooling effect. Overall, microcontroller-based split inverter AC enables real�time performance monitoring and efficient operation, representing a promising technology.

Item Type: Article
Subjects: Ilmu Teknik > Ilmu Keteknikan Industri > Teknik Refrigerasi
Divisions: Jurusan Teknik Mesin > Prodi D3 Teknik Pendingin dan Tata Udara > Publikasi
Depositing User: I Gede Artha Negara
Date Deposited: 06 Feb 2024 06:16
Last Modified: 06 Feb 2024 06:16
URI: http://repository.pnb.ac.id/id/eprint/10536

Actions (login required)

View Item View Item